Orthopedic Surgical Trauma Instrument Orthopedic Surgical Trauma Instrument Multi Dual Function Bohrsagensystem

Product Description

Product Description

Multi function Bohrsägensystem

It has a greater generator, providing stable and powerful performance for medical surgical procedures.

Bohrsägensystem 1
Bohrsägensystem 2
Bohrsägensystem 3

Technical Specification

No. Parameter Data
1Battery typeNi-MH battery
2Battery capacity1800mAh
3Operation(V) voltage14.4V
4Radial circle run-out≤0.1mm
5Axial movement≤0.5mm
6Biggest drill bit diameter8mm
7Diameter of Cannulation4.5mm
8Sterilization≤135℃
9Noise≤75dB

Important Notes

Sterilize temperature ≤ 135 °C (Improved type ≤ 155 °C ). Exceeding this temperature may damage the motor.
Normal bone drill capacity: holds drill bits < 6 mm. Reaming drill torque: ~300 rpm. Hollow drill: ~600 rpm.
Battery maintenance: Must be removed after surgery to prevent automatic discharge and prolong battery life.
Battery sterilization: The battery is not resistant to high temperatures and cannot be sterilized.
Cleaning: Wash the cranial bur immediately after surgery to avoid blood sticking, then dry thoroughly.
Storage: Ensure the battery space in the handpiece remains dry after sterilization.
Blade Usage: Cranial bur blades are flexible medical stainless steel; we suggest using each blade for only one surgery.

Certification

Certification

Exhibition

Exhibition

Frequently Asked Questions

Q1: What type of battery does the system use?
The system uses a high-capacity 1800mAh Ni-MH battery with an operating voltage of 14.4V.
Q2: Can the battery be sterilized in an autoclave?
No, the battery is not resistant to high temperatures and must not be sterilized. Only the handpiece (without battery) and bits are autoclavable.
Q3: What is the recommended sterilization temperature for the tool?
The standard sterilization temperature is ≤ 135 °C. For improved types, it can handle up to 155 °C.
Q4: How should the cranial bur be maintained after surgery?
It must be washed immediately after the procedure to prevent blood from drying in the bur, and then it should be thoroughly dried.
Q5: What is the maximum drill bit diameter supported?
The system supports a biggest drill bit diameter of 8mm, while the cannulation diameter is 4.5mm.
Q6: Why should the battery be removed immediately after surgery?
Removing the battery prevents small automatic discharges that can significantly shorten the overall battery life.